Sas2008 b2. NVDATA Device ID and Chip Revision match verified.
Sas2008 b2. 2204) Intel Core i9-13900k (now back to 12900k) Nov 18, 2015 · Then I tried to install Win7 X64 Ultimate on the Raid0 in UEFI mode. So I'm guessing I can go ahead and put them in my server and replace the Marvell adapters without problems? Mar 4, 2019 · Sorry you're having trouble. I honestly have no idea what LSI card is equal to what, I am guessing that LSI 9211 = IBM 9200 = SAS2008 chip. 00. Having said that, I read about cross-flashing Mar 4, 2024 · Hi, I have two issues, not sure if they are related or not. Example: And for one of my pools the size is not reporting and only delivering a '?'. 31. Apr 16, 2023 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:05:00:00 SAS Address : 5b82a72-0-ce7f-4f00 Feb 23, 2017 · 1 x 9201-8i (SAS2008) - 8 ports, 2 x 8087 going to internal 8087-8088 bracket then 2 x 8088 out to the 3U chassis I've just seen an eBay listing for several 9205-8e cards (2308 chipset). e. 0 on pci8 mps0: Firmware May 3, 2011 · Windows 11 Pro Corsair AX1600i Aquaero 6 Pro USB Asus ROG Maximus Z690 Extreme E-ATX (lates BIOS v. 00 Checking for a compatible NVData image NVDATA Device ID and Chip Revision match verified. 00 NVDATA Vendor : LSI NVDATA Product ID : SAS9211-8i BIOS Version : N/A UEFI BSD Version : N/A FCODE Feb 21, 2013 · mps0: <LSI SAS2008> port 0xe000-0xe0ff mem 0xf7bc0000-0xf7bc3fff,0xf7b80000-0xf7bbffff irq 16 at device 0. This seems to impact: Small old files such as mp3 which have been carried across through various ext3, ext4, and NTFS file systems over the last 25 years. 500605b006081990 (0:8:0. Still stock firmware in Mar 17, 2020 · C:\SAS2FLSH. 0-U5. 00, Driver: 14. On review, when restoring from the (Pre ZFS) backup these files may already be corrupted Jun 19, 2022 · I'm looking into buying this Dell H200 in IT Mode to add SATA ports to my Truenas system Apr 28, 2017 · Hello, I am new to upgrading FreeNAS firmware. To download the correct file, head over to Broadcom’s product pages and select your model of HBA card, in my case the 9211 which is a 6Gb/s model. %PDF-1. 00 ERROR: Failed to Upload Image! Firmware Image Validation Failed! Feb 3, 2019 · Hi All, I am having issues with LSI SAS HBA's I had a HP DL380g6 running two 921x-8i HBA's with BIOS enabled I added a 9201-16e I had all kinds of issues upgrading from 9. 2-U8 Board: Supermicro X10SRL-F with Intel Xeon E5-2667 v4 @ 3. 2-U8 on a Dell Poweredge T310 on an aftermarket OEM LSI HBA card already in IT mode, that I thought was an LSI 9211-8i, but it turns out its actually an OEM IBM 9200 / SAS2008. 01 Controller: SAS2008(B2) Firmware product ID: 0x2213 (IT) Firmware Version: 20. In Storage->Disks I have a lot of N/As for Pool associatations. I think the previous SAS2 version use the mps driver so 'dmesg | grep mps'. 72TB healthy usable space) and one 1TB NVMe (for development May 21, 2017 · Adapter Selected is a LSI SAS: SAS2008(B2) LSI SAS2008 HBA Sharkoon T9 Value with 2 * Icy Dock FatCage MB153SP-B 3-in-2 drive cages Seasonic X-650. 08 Firmware Product ID : 0x2213 (IT) Firmware Version : 20. 00 ERROR: Failed to Upload Image! Firmware Image Validation Failed! Mar 30, 2023 · LSI Logic MPT Configuration Utility, Version 1. 2, the only way I was able to get the upgrade to work was disable the cards in the BIOS, yank all the Jan 2, 2024 · Backup: TrueNAS 13 Supermicro X10SLM+-F with Intel Core i3-4330 and 2*8GB Crucial ECC DDR3 1600MHz 6 * WD30EFRX WD Red 3TB in RAIDZ2 and 1 * Toshiba/OCZ TR200 (boot) Nov 1, 2010 · That is something I will likely go over in the Supermicro X8SI6-F review. NVDATA Vendor: LSI NVDATA Product ID: SAS9210-8i BIOS Version: 07. 08. 00 00:06:00:00 Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:02:00:00 SAS Address : 5b8ca3a-0-f37a-4500 NVDATA Version (Default) : 14. 00 - here is the guide. 00 NVDATA Vendor : LSI NVDATA Product ID : SAS9211-8i BIOS Version : N/A UEFI BSD Version : N/A Jan 4, 2020 · So when I got my IBM x5650 m3's they came with 2 LSI SAS9212-4i4e (IBM 6gb sas hba) each. 1 and 11. Dec 13, 2014 · I used 'dmesg | grep mpr' to find the driver and firmware versions (SAS3). Aug 5, 2020 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:01:00:00 SAS Address : 5000xxx-x-xxxx-xxxx NVDATA Version (Default) : 14. I purchased a flashed (IT mode) DELL H200E (LSI 9200-8E) card and am using a SFF8088 to SATA breakout cable to an enclosure and am not having any luck with TrueNAS Core detecting the disks. Apr 18, 2012 · The LSI SAS 2008 is a 6. I currently have Supermicro x8dth-6f-o motherboard. I am running a PERC H730 mini (in HBA mode) and a SAS2008(B2) flashed to IT Mode Stack Exchange Network. Advanced Mode Set Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. (Note that they may be Welcome to your friendly /r/homelab, where techies and sysadmin from everywhere are welcome to share their labs, projects, builds, etc. Aug 24, 2015 · Attempting to flash firmware to LSI SAS SAS2008(B2) : Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. I am getting the following warning: WARNING Mar 31, 2014 · I replaced the PERC H200 with a LSI SAS9211-8i, it's the same chipset SAS2008, but the LSI has a PCIe 8x connector. So I'm finally using them for an external diskshelf (EMC Feb 9, 2017 · BACON: FreeNAS 11. Valid Initialization Image verified. 05. I've shut down the system multiple times but no luck. EXE -o -e 6 Advanced Mode Set Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Erase Flash Erasing Flash Region Erase Flash Operation Successful! Resetting Adapter Reset Successful! Finished Processing Commands Successfully. 01. Here are the steps I took to f AFAIK, all LSI SAS 2008 chipset based HBAs are no longer supported in ESXi 7 due to them permanently dropping support for vmklinux drivers (a shim that allows linux compiled drivers to run on the hypervisor). This is LSI2008 RAID card driver useD on Cloud Products support OS Windows Server 2008 R2 SP1 English 64 bit Dec 16, 2020 · 0 SAS2008(B2) 20. 08 Firmware Product ID : 0x2213 (IT Jun 29, 2023 · Hello. 1 Im running 10 storage disks on this, two on the on board SATA and the other 8 on the HBA Everything works fine, my pools are up and running and everything. 0gbs SAS 2 or SATA III based controller that features eight ports and native PCIe connectivity. A note about the forum first. NVDATA Version 09. Stack Exchange network consists of 183 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. Jul 19, 2018 · So I finally purchased a hba to expand my drive pool but I'm concerned about firmware. If someone is looking at the forum from a mobile device like a tablet or phone, as I am this morning, they can't see the signature information. 00 NVDATA Vendor : LSI NVDATA Product ID : SAS9211-8i BIOS Version : N May 3, 2011 · C:\LSIMEGA\SAS2FLSH. May 3, 2011 · Advanced Mode Set Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. 00, Driver: 05. In the forums we have maintained a LSI Controller Mapping between LSI controllers and their OEM counterparts. 0 G, 6. Chapter 2 provides an introduction to the LSI 2008 SAS MegaRAID Software Util-ity settings and how to run the LSI 2008 SAS MegaRAID Confi guration Utility on the IR Mode. , for some reason erasing the BIOS doesn't work with the Linux version, but if you just need to update firmware it can be easily done with Unraid. Oct 15, 2020 · Best to use the DOS or UEFI tools to do any crossflashing and/or other more advanced options, e. Chapter 3 provides instructions on how to run the LSI 2008 SAS MegaRAID Con-fi guration Utility on the IMR Mode. The purpose of this is to connect to a storewize v3700. 255. In comes a solution: firmware flashing, or more specifically, flashing to a passthrough (IT) firmware, as opposed to the RAID (IR) firmware on the cards by default. Jun 26, 2019 · I hope my personal experience on this is helpful for others! I utilized OCR software to capture some of the command outputs in text format. Before I had a May 3, 2011 · LSI MegaRAID. I upgraded the firmware and the driver as per HCL # esxcfg-scsidevs -a. 00 NVDATA Vendor : LSI NVDATA Product ID Dec 9, 2020 · So I have drives, I have my AOC-USAS2-L8A-IS018 (LSI SAS2008 based), but none of those drives attached to the RAID controller are usable in proxmox . Exiting SAS2Flash. 0) LSI Logic / Symbios Logic LSI2008 # vmkload_mod -s mpt2sas |grep Version Jan 30, 2021 · The hardware specs are: AMD EPYC 3202, ASRock Rack ROMED8-2T, 256 GB ECC RAM, LSI SAS2008 HBA, Samsung 980 Pro SSD (m2) The VM specs are: Gen 2 VM, Secure Boot Disabled, 8GB RAM, 4 Virtual Processor, 128 GB VHDX for OS install, Virtual NIC, All Integration Services offered, No Checkpoints Aug 3, 2024 · Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:02:00:00 SAS Address : 5b8ca3a-0-f37a-4500 NVDATA Version (Default) : 14. 0 G, down, down B___T___L Type Vendor Product Rev SASAddress PhyNum 0 0 0 Disk ATA INTEL SSDSC2BA80 0265 4433221100000000 0 0 1 0 Disk ATA Sep 25, 2014 · [root@new_nas] ~# dmesg|grep -i mps mps0: <LSI SAS2008> port 0x3000-0x30ff mem 0xd8440000-0xd844ffff,0xd8400000-0xd843ffff irq 16 at device 0. Valid NVDATA Image found. log Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:01:00:00 SAS Address : 5xxxxxx-x-xxxx-xxxx NVDATA Version (Default) : 14. Firmware Version 16. I need to data off this pool. That's something which generally seem to be missing from forum posts on this topic. Update: Convert your LSI MegaRAID controller card with LSI SAS2008 chipset to a Plain SAS2008 controller card (IT or IR mode), will look and feel like a LSI SAS9211-8i, and will be ready to use with unRAID (BIG THANKS to KKM for creating the empty. The prepared stick with the driver is found, the lsi_sas2. I read that LSI is preferrable and I was relieved to see my hardware is LSI. 00 Firmware Image compatible with Controller. I have been testing the X8SI6-F and the LSI 9211-8i in the same system, just moving the SFF-8087 cables between the two. Firmware Image compatible with Controller. 04 07. Just installed two (2!) SAS controllers to a Supermicro X10SLM+-F and the systems don't boot past the SAS firmware check. rom Advanced Mode Set Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. Dec 2, 2017 · Intel E3-1230v5 (3. 2GHz, 128GB RAM Case: Supermicro SC826BE1C-R920LPB 3U 12-bay with BPN-SAS3-826EL1 backplane Aug 6, 2024 · Hi all, Im new to all of this so I am reading away at various posts on things that can cause issues. May 22, 2018 · C:\SAS2FLSH. One of them is the HBA hardware used. My HBA is LSI SAS2008 with the most recent firmware (P20). The stick with the Win7 iso boots, and at some point in time the missing driver for the SAS card is detected. May 11, 2020 · Running Freenas 11. 15. My reading led me to use the sas2flash -list command to dump the firmware information. Sep 9, 2021 · System: Supermicro X10SLM-F with an IT flashed LSI 9220 8i Boot disks on flashdrives TrueNAS-12. Here is a guide of how to fix a LSI 9211-8i SAS Controller. 4 %âãÏÓ 193 0 obj > endobj xref 193 60 0000000016 00000 n 0000002066 00000 n 0000002213 00000 n 0000002817 00000 n 0000003413 00000 n 0000003835 00000 n 0000004384 00000 n 0000004421 00000 n 0000004602 00000 n 0000004716 00000 n 0000005344 00000 n 0000005896 00000 n 0000005985 00000 n 0000006594 00000 n 0000007098 00000 n 0000007189 00000 n 0000008277 00000 n 0000008767 00000 n Nov 15, 2022 · [EDIT]Yeah I went ahead & fixed this by booting into UEFI shell & flashing the firmware to version 20. Software Jul 17, 2015 · We've recently installed a LSI SAS2008 (also known as a LSI SAS 9211 8i) HBA on our machine here. . Which version should I be running? This is what I have now. Probably this is the wrong wiring in my case, but the issue in its current state appeared just last week after the upgrade to the recent Scale beta. Sorry for phone screenshot. 10 to 11. I have read and searched quite a bit, but found conflicting answers, so here I am writing this post. 00-fbsd. 3. 1 does see the drives connected just fine as it does act as JBOD as long as you don't configure RAID, but I also want to upgrade the Firmware and switch to IT mode. The cards are: LSI SAS 9212-4i4e LSI SAS 9211-4i If I only use one card at a time, all is OK. Here's the output of sas2flash -list Nov 18, 2014 · Adapter Selected is a LSI SAS: SAS2008(B2) Num Ctlr FW Ver NVDATA x86-BIOS PCI Addr 0 SAS2008(B2) 16. 70, July 30, 2013 1 MPT Port found ===== ioc0 LSI Logic SAS2008 B2 MPT 200 Firmware 0e000000 IOC 0 SAS2008's links are 6. I’ve been having intermittent problems with random files coming up as “permanent errors” (see export below). Please correct me if I'm wrong. Have been using FreeNAS for about 6 months now. Apr 12, 2024 · Hi All, Sorry for long first post. 08 No Image 00:0b:01:00 definitely looks like no bios it doesn't really add that much time to the boot (the mobo takes like 8 minutes anyway), so i usually just leave it there so I don't have to add it later if I need to boot with that card ever. First time working with SAS controllers. all disks from the EMC disk enclosure), lsblk reports those disks twice. 00 NVDATA Vendor : LSI NVDATA Product ID : SAS9211-8i BIOS Version : N/A UEFI BSD Version : N/A Feb 21, 2024 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) SAS2008 not listing any disks. vmhba0 mpt2sas link-n/a sas. Sep 3, 2016 · sas2flsh -c 0 -list -l hba-1. Firmware Version 07. bin Advanced Mode Set Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. URL or two in there are a bit out of date, but if you look at what it was posted & what is available at the general github link you should be able to figure out that this is what would be the relevant link for steps 9. bin -b mptsas2. Firmware Version 09. 1 which requires v20 IT firmware to be installed. However ubuntu is able to see/map/mount them. Feb 2, 2017 · Download firmware. The storewize is mapped to to the machine, and upon boot we can see the mapped volumes appear in the BIOS. NVDATA Version 07. inf loads and shows that the SAS2008 Falcon storport driver needs to be loaded. 08 NVDATA Version (Persistent) : 11. Jul 12, 2024 · I have an exported pool (GeneralStorage) which when I attempt to import either via gui or via “zpool import GeneralStorage” causes the system to reboot. 02. 39. Feb 1, 2022 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:05:00:00 SAS Address : 500605b-0-0552-0970 Jun 30, 2022 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:01:00:00 SAS Address : 5000xxx-x-xxxx-xxxx NVDATA Version (Default) : 14. bin, so you dont need to have to worry about which sbr to obtain and use. We are going to be using this card with FreeNAS 9. Sep 13, 2024 · Hi everyone. You got me on the right track, good call. Sep 26, 2017 · Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:01:00:00 SAS Address : SSSSSSSSSSSSSSSSSSSSSSSS NVDATA Version (Default) : 11. Where do I go from here? root@TrueNas[~]# zpool import pool: GeneralStorage id: 7433741377666261024 state: ONLINE status: Some supported features are not enabled on the pool. 0 on pci1 mps0: Firmware: 16. 08 NVDATA Version (Persistent) : 14. I have the similar issue as the topic starter in this thread, 25 disks unassigned (i. I have read this, this, this, this, and this. The system devices of the first server with a sas2008 card also mentions "Serial Attached SCSI controller: Broadcom / LSI SAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon] (rev 03)", NOT a RAID bus controller. exe -c 0 -list 可以得到相关的SAS信息 Adapter Selected is a LSI SAS: SAS2008(B2) Controller Number : 0 Controller : SAS2008(B2) PCI Address : 00:01:00:00 SAS Address : 5000xxx-x-xxxx-xxxx NVDATA Version (Default) : 14. I am definitely going to buy one, to replace the 9201-8i I have on my external ports (removing the need for the internal 8087-8088 bracket and 2 x internal Sep 1, 2017 · I have two rather large servers with identical hardware (Dual Opteron with Supermicro's H8DG6-F motherboard and three LSI SAS 9211-8i cards in IT-mode), but one of them seem to hang at a particular point during the boot process from time to time (Please see the attached screenshot of the May 3, 2011 · C:\5_LSI_~1\SAS2FLSH. I got a line that looked like this: mpr0: Firmware: 05. Valid BootLoader Image verified. g. NVDATA Device ID and Chip Revision match verified. jeneeben; Jan 1, 2024; TrueNAS SCALE Dec 30, 2021 · Well, most questions have been asked and answered before, but there's an overwhelming amount of stuff to know, especially with fiddly stuff like needing magic firmware on cards that don't normally take it. 00 14. 00 10. I purchased a card from ebay that was not showing during the post. Apr 5, 2015 · I have an ASUS PIKE 2008 (LSI SAS: SAS2008(B2) Chipset: LSISAS 2008) installed on a ASUS Z9PE-D16 2/L and it is running in IR Mode and FreeNAS 11. EXE -l Flashlog. 4GHz) Skylake CPU | Supermicro X11SSM-F | 64 GB Samsung DDR4 ECC 2133 MHz RAM | One IOCREST SI-PEX40062 4 port SATA PCI-E (in pass-thru for NAS Drives) | 256 GB SSD Boot Drive | 1TB Laptop Hard Drive for Datastores | Three HGST HDN726060ALE614 6TB Deskstar NAS Hard Drives and one Seagate 6TB Drive (RAIDZ2, 8. txt -o -f 2118it. Mar 20, 2020 · 移除多余的SAS卡,及磁盘,单纯使用FREEDOS启动盘启动 sas2flsh. The HW was recently refreshed from Nov 4, 2018 · Hello. 07. 00 NVDATA Vendor : LSI NVDATA Product ID : SAS9211-8i BIOS Version : N/A UEFI BSD Version : N/A FCODE Jul 9, 2018 · Adapter Selected is a LSI SAS: SAS2008(B2) Executing Operation: Flash Firmware Image Firmware Image has a Valid Checksum. 06. A Dell PERC H310 was flashed, using a Dell PowerEdge R720xd. svpyo xcupbe lwce qicph ycjt opjwchx ctalnj uhcu ztc xon